Product parameters
    Description

    Specifications: 

    SS1102T 105x14x45 ° angle bend, SS1104T 105x14x45 ° angle bend,


    SS1105T 108x14x45 corner bend, SS1109T 85x14x45 "corner bend,


    SS1111T 120x14x45 ° angle bend, SS1112T 120x14x45 ° angle bend,


    SS1107T 108x14x45 ° angle bend, SS1115T 90x14x45 ° angle bend,


    SS1117T 110X14X45 ° bend, SS1123T 105x14x45 ° bend



    [Product Name]

     Titanium alloy tear forceps


    [Model/Specification] 

    Curved, angular, Huff shaped, Huff shaped, round handle curved, and round handle angular.


    [Name of Filing Person/Production Enterprise] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise]

     No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Contact Information]

    Phone: 18360220578 Postal code: 223900

    Fax: 0527-89886598 Email: 541895054@qq.com


    [After sales Service Unit] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Production Filing Certificate No.] 

    Susu Food and Drug Supervision Instrument Production Preparation No. 20194005


    [Medical Device Filing Certificate Number]


    [Product Technical Requirements Number]

    The product's performance, structural composition, and scope of application are composed of a pair of tail stacked blades. Made of 05Cr17Ni4Cu4Nb material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, a smooth surface, and is sterilized by the user according to the instructions before use. Used for gripping eye tissue and intraocular foreign bodies.


    [Contraindications] None


    [ Precautions] 

    When using high-pressure steam sterilization, the titanium alloy tear forceps must not be closed, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the tail rivet to break. Used by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use titanium alloy tear forceps when they deform, break, or rust;

    2. Non professionals are strictly prohibited from repairing deformed angle bending titanium alloy tear forceps.


    [Instructions for Use]

    1. High temperature and high pressure sterilization is required before use of the product;

    2. When clamping the capsule membrane during use, the force should be moderate and the head should not be misaligned;

    3. After use, titanium alloy tear forceps should be cleaned promptly.


    [Product maintenance and upkeep methods]

    1. After the surgery, the remaining stains on the titanium alloy tear forceps should be washed clean in a timely manner, and dried for later use;

    2. Titanium alloy tear forceps should be stored in a box with soft materials as padding to prevent collisions between the titanium alloy tear forceps and damage to the inner plane of the titanium alloy tear forceps head.


    [Storage]

    Titanium alloy capsule forceps should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years