Product parameters
    Description

    Specifications: 

    SS2117G 120x10 straight head without lock,SS2117T120x10 straight head without lock,

    SS2118G 120x10 Elbow without lock,SS2118T120x10 Elbow without lock



    Product Name: Curved Need Holder


    Specifications

    SS2117G 120x10 straight head without lock, SS2117T120x10 straight head without lock,

    SS2118G 120x10 Elbow without lock, SS2118T120x10 Elbow without lock


    [Name of Filing Person/Production Enterprise] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise]

     No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [After sales Service Unit] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Production Filing Certificate No.] 

    Susu Food and Drug Supervision Instrument Production Preparation No. 20194005

    The performance, structural composition, and scope of application of the product are composed of a head and a handle, with the head as the interface. Made of 32Cr13Mo material specified in GB/T 1220-2007 or TC4 material specified in GB/T 2965-2007. Non sterile provision. Before use, sterilize according to the instructions provided by the user organization. Not to be used under the endoscope. The product has good corrosion resistance, smooth surface, and good clamping function. Used to connect instruments (blades).


    [Contraindications] None


    [ Precautions ]

    During high-pressure steam sterilization, the blade holder must not be closed, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the head rivet to break. Operated by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use the blade gripper when it deforms, fractures, or rusts;

    2. Non professionals are strictly prohibited from repairing deformed blade holders.


    [Instructions for Use]

    1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;

    2. When connecting instruments during use, the force should be moderate and the head should not be misaligned;

    3. After use, the blade holder should be cleaned promptly.


    [Product maintenance and upkeep methods]

    1. After the surgery, the remaining stains on the blade holder should be washed clean in a timely manner, and dried for later use;

    2. The blade gripper should be stored in a box with soft materials as padding to prevent collision between the blade grippers and damage to the blade gripper head.


    [Storage]

    The blade holder should be stored in an indoor environment with an ambient temperature of 0-40 ℃, a relative humidity not exceeding 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years