    Specifications: 

    SS3018G 120x20 Curved blunt head,SS3019G 120x20 Curved blunt head



    Product Name: Conjunctival Scissors


    [Model/Specification]

    Curved pointed head, curved blunt head.


    [Name of Filing Person/Production Enterprise]

    Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise]

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address]: No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [After sales service unit]

    Suqian Shengshi Medical Equipment Co., Ltd


    [Production Filing Certificate No.]

    Su Su Food and Drug Supervision Equipment Preparation No. 20194005

    The product's performance, structural composition, and scope of application are composed of a pair of blades connected in the middle, with a cutting edge at the head. Made of 20Cr13 material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, and good shear function. Before use, the user organization sterilizes it according to the instructions. Used for cutting eye tissue.


    [Contraindications] None


    [Precautions] 

    During high-pressure steam sterilization, the conjunctival shear must not be closed, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the head rivet to break. Used by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use the conjunctival shear when it undergoes deformation, fracture, or corrosion;

    2. Non professionals are strictly prohibited from repairing deformed conjunctival scissors.


    [Instructions for Use]

    1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;

    2. When cutting the conjunctival tissue inside the eye during use, it should not exceed 2/3 of the cutting edge of the conjunctiva;

    3. After use, the conjunctival scissors should be cleaned in a timely manner.


    [Product maintenance and upkeep methods]

    1. After the surgery, the remaining stains on the conjunctiva should be washed clean and dried for later use.

    2. The conjunctival scissors should be stored in a box with soft materials as padding to prevent them from colliding with each other and damaging the cutting edge of the conjunctival scissors.


    [Storage]

    The conjunctival scissors should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years