Specifications: SS2101G120x11 straight head without lock, SS2101T 120x11 straight head without lock, SS2103G 120x11 elbow without lock, SS2103T 120x11 elbow without lock, SS2105G120x11 straight head without lock, SS2105T 120x11 straight head without lock, SS2109G 120x10 elbow without lock, SS2109T120x10 elbow without lock, SS2110G 120x10 blunt head, SS2110T 120x10 blunt head, SS2111G 120x10 blunt head, SS2111T120x10 blunt head, SS2107G120x10 blunt head x11 elbow without lock, SS2107T120x11 elbow without lock, SS2112G140x11 straight head without lock, SS2112T140x11 straight head without lock, SS2114G 140x11 elbow without lock, SS2114T 120x11 elbow without lock, SS2116G 130x10 straight head without lock, SS2116T 130x10 straight head without lock
[ Product Name ]
Needle holding forceps for microscopic eyes
[Model/Specification]
Straight Unlocking/12mm, 14mm, 16mm, 18mm; Curved without lock/12mm, 14mm, 16mm, 18mm, while curved with lock/12mm, 14mm, 16mm, 18mm.
[Name of Filing Person/Production Enterprise]
Suqian Shengshi Medical Equipment Co., Ltd
[Name and Address of Filing Person/Production Enterprise]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[Production Address]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[After sales Service Unit]
Suqian Shengshi Medical Equipment Co., Ltd
[Production Filing Certificate No.]
Susu Food and Drug Supervision Instrument Production Preparation No. 20194005
The product's performance, structural composition, and scope of application are composed of two pieces connected in the middle, with a beak at the head. Made of 32Cr13Mo material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, and good clamping ability. Before use, the user organization sterilizes it according to the instructions. Used for clamping eye tissue and instruments.
[Contraindications] None
[ Precautions]
When using high-pressure steam sterilization, do not use needle holding pliers to close the microscopic eye, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the head rivet to break. Used by professional medical personnel.
[Warning]
1. It is strictly prohibited to use the needle holding pliers when the microscope eye undergoes deformation, fracture, or corrosion;
2. Non professionals are strictly prohibited from using needle holding pliers to repair deformed microscopic eyes.
[Instructions for Use]
1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;
2. When using forceps to clamp eye tissue or instruments, it should not exceed 2/3 of the beak of the needle holding forceps used for microscopic eyes;
3. After use, the microscope eye should be cleaned in a timely manner with a needle holding forceps.
[Product maintenance and upkeep methods]
1. After the surgery, the remaining stains on the micro eye should be washed clean with a needle holding forceps in a timely manner, and dried for later use.
2. The micro eye needle holding pliers should be stored in a box with soft materials as padding to prevent collision between the micro eye needle holding pliers and damage to the inner plane of the micro eye needle holding pliers head.
[Storage]
The micro eye needle forceps should be stored in an indoor environment with an ambient temperature of 0-40 ℃, relative humidity not exceeding 80%, no corrosive gas, and good ventilation.
[Production Date]
Please refer to the label for details
[Service life]
8 years