Specifications:
SS1102G 105x14x45 ° angle bend, SS1104G 105x14x45 ° angle bend,
SS1105G 108x14x45 corner bend, SS1109G 85x14x45 "corner bend,
SS1111G 120x14x45 ° angle bend, SS1112G 120x14x45 ° angle bend,
SS1107G 108x14x45 ° angle bend, SS1115G 90x14x45 ° angle bend,
SS1117G 110x14x45 ° bend, SS1123G 105x14x45 ° bend
[Product Name]
Stainless Steel Tearing Forceps
[Model/Specification]
Curved, angular, Huff shaped, Huff shaped, round handle curved, and round handle angular.
[Name of Filing Person/Production Enterprise]
Suqian Shengshi Medical Equipment Co., Ltd
[Name and Address of Filing Person/Production Enterprise]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[Production Address]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[Contact Information]
WeChat/:+8615851438190
[After sales Service Unit]
Suqian Shengshi Medical Equipment Co., Ltd
[Production Filing Certificate No.]
Susu Food and Drug Supervision Instrument Production Preparation No. 20194005
[Medical Device Filing Certificate Number]
[Product Technical Requirements Number]
The product's performance, structural composition, and scope of application are composed of a pair of tail stacked blades. Made of 05Cr17Ni4Cu4Nb material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, a smooth surface, and is sterilized by the user according to the instructions before use. Used for gripping eye tissue and intraocular foreign bodies.
[Contraindications] None
[ Precautions]
During high-pressure steam sterilization, stainless steel tear forceps must not be closed, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the tail rivet to break. Used by professional medical personnel.
[Warning]
1. It is strictly prohibited to use stainless steel tear forceps when they deform, break, or rust;
2. Non professionals are strictly prohibited from repairing deformed angle bending stainless steel tear forceps.
[Instructions for Use]
1. High temperature and high pressure sterilization is required before use of the product;
2. When clamping the capsule membrane during use, the force should be moderate and the head should not be misaligned;
3. After use, the stainless steel tear forceps should be cleaned in a timely manner.
[Product maintenance and upkeep methods]
1. After the surgery, the remaining stains on the stainless steel tear forceps should be washed clean and dried for later use;
2. Stainless steel tear forceps should be stored in a box with a soft material lining to prevent collision between the stainless steel tear forceps and damage to the inner surface of the head of the stainless steel tear forceps.
[Storage]
Stainless steel bag forceps should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.
[Production Date]
Please refer to the label for details
[Service life]
8 years