Specifications:
SS4018GSS4018T 120x14x0.5 Arc-shaped,120x14x0.5 Arc-shaped,
SS4019G120x14x0.7 Arc-shaped,SS4019T 120x14x0.7 Arc-shaped,
SS4020T 120x14x1.4 Arc-shaped,SS4021G 120x14x0.5/1.5 Arc-shaped,SS4021T 120x14x0.5/1.5 Arc-shaped,
SS4022G120x25x1.2 Straight type,SS4022T 120x25x1.2 Straight type,
SS4023G120x25x1.7 Straight type,SS4023T 120x25x1.7 Straight type
[Product Name]
Iris Restorer
[Model/Specification]
Single head (0.5mm, 0.7mm, 1.0mm), double head (0.5mm, 0.7mm, 1.0mm).
[Name of Filing Person/Production Enterprise]
Suqian Shengshi Medical Equipment Co., Ltd
[Name and Address of Filing Person/Production Enterprise]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[Production Address]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[After sales Service Unit]
Suqian Shengshi Medical Equipment Co., Ltd
[Production Filing Certificate No.]
Susu Food and Drug Supervision Instrument Production Preparation No. 20194005
The product's performance, structural composition, and scope of application are composed of a proximal handle and a distal needle body connected together. Made of 12Cr18Ni9 material specified in GB/T 1220-2007 or TC4 material specified in GB/T 2965-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, easy operation, and is sterilized by the user according to the instructions before use. Used for eye tissue reduction.
[Contraindications] None
[Precautions]
During high-pressure steam sterilization, it should never be stacked together with other instruments, otherwise it may cause deformation of the head under stress. Used by professional medical personnel.
[Warning]
1. When the iris restorer undergoes deformation, fracture, or rust, it is strictly prohibited to use it;
2. Non professionals are strictly prohibited from repairing deformed iris restorers.
[Instructions for Use]
1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;
2. After use, the iris restorer should be cleaned promptly.
[Product maintenance and upkeep methods]
1. After the surgery, the remaining stains on the iris restorer should be washed clean and dried for later use;
2. Iris restorers should be stored in boxes with soft materials as padding to prevent collisions and damage to the head of the iris restorer.
[Storage]
Iris restorers should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.
[Production Date]
Please refer to the label for details
[Service life]
8 years