Your Location:
Product parameters
    Description

    Specifications: 

    SS4025G120 Angled blunt headed,SS4025T 120 Angled blunt headed,

         SS4026G120 Straight blunt headed,SS4026T 120 Straight blunt headed,

             SS4027G 120 Straight blunt headed,SS4027T 120 Straight blunt headed


    [Product Name

    Iris Hook


    [Name of Filing Person/Production Enterprise] Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [After sales Service Unit] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Production Filing Certificate No.] 

    Susu Food and Drug Supervision Instrument Production Preparation No. 20194005


    [Medical Device Filing Certificate Number]


    [Product Technical Requirements Number]

    The product's performance, structural composition, and scope of application are composed of a head and a rod, with a hook head on the head. Made of 06Cr19Ni10 material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, and good traction function. Before use, the user organization sterilizes it according to the instructions. Used for hooking and pulling eye tissue.


    [Contraindications] None


    [ Precautions ] During high-pressure steam sterilization, it is absolutely not allowed to collide with other objects, otherwise it will affect the use function. In addition, during high-pressure steam sterilization, thermal expansion can also cause head breakage. Operated by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use the iris hook when it deforms, breaks, or rusts;

    2. Non professionals are strictly prohibited from repairing deformed iris hooks.


    [Instructions for Use]

    1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;

    2. After use, the iris hook should be cleaned in a timely manner.


    [Product maintenance and upkeep methods]

    1. After the surgery, the remaining stains on the iris hook should be washed clean and dried for later use.

    2. The iris hook should be stored in a box with a soft material cushion to prevent collision and damage to the head of the iris hook.


    [Storage]

    Iris hooks should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life] 

    8 years




    • User name Member Level Quantity Specification Purchase Date
    • Satisfaction :
    No evaluation information