Your Location:
Product parameters
    Description

    Specifications: 

    SS3007G 120x16 blunt, SS3007T 120x16 blunt, SS3008G 120x16 blunt, SS3009G 120x16 blunt, SS3010G120x16 blunt, SS3011T120x16 blunt,


    SS3012G120x16 straight blunt, SS3012T120x16 straight blunt, SS3003G120x16 straight pointed, SS3001T120x16 curved pointed



    [ Product Name ] 

    Corneal Scissors


    [Model and Specification] 

    Curved pointed head/12mm, 14mm, 16mm, curved blunt head/12mm, 14mm, 16mm, straight pointed head/12mm, 14mm, 16mm, straight blunt head/12mm, 14mm, 16mm.


    [Name of Filing Person/Production Enterprise] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Production Filing Certificate No.] 

    Susu Food and Drug Supervision Instrument Production Preparation No. 20194005

    The product's performance, structural composition, and scope of application are composed of a pair of blades connected in the middle, with a cutting edge at the head. Made of 20Cr13 material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, and good shear function. Before use, the user organization sterilizes it according to the instructions. Used for cutting eye tissue.


    [Contraindications] 

    None


    [Precautions]

    During high-pressure steam sterilization, the corneal scissors must not be closed, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause joint fractures. Used by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use corneal scissors when they deform, break, or rust;

    2. Non professionals are strictly prohibited from repairing deformed corneal scissors.


    [Instructions for Use]

    1. High temperature and high pressure sterilization is required before use of the product;

    2. When cutting eye tissue during use, it should not exceed 2/3 of the corneal cutting edge;

    3. After use, the corneal scissors should be cleaned promptly.


    [Product maintenance and upkeep methods]

    1. After the surgery, the residual stains on the cornea should be washed clean and dried for later use.

    2. Corneal scissors should be stored in a box with soft materials as padding to prevent collisions between the scissors and damage to the cutting edge.


    [Storage]

    Corneal scissors should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years



    • User name Member Level Quantity Specification Purchase Date
    • Satisfaction :
    No evaluation information