Your Location:
Product parameters
    Description

    Specifications: 

    SS4047G 120 single-head,SS4047T 120 single-head



    Product Name: Intralasik Flap Spatula


    Specifications: SS4047G 120 single head, SS4047T 120 single head


    [Name of Filing Person/Production Enterprise] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [After sales Service Unit] 

    Suqian Shengshi Medical Equipment Co., Ltd

    The product's performance, structural composition, and scope of application are composed of a head and a rod, with a hook head on the head. Made of 06Cr19Ni10 material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, and good traction function. Before use, the user organization sterilizes it according to the instructions.


    [Contraindications] None


    [ Precautions ]

    During high-pressure steam sterilization, it is absolutely not allowed to collide with other objects, otherwise it will affect the use function. In addition, during high-pressure steam sterilization, thermal expansion can also cause head breakage. Operated by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use Intralasik Flap Spatula when it undergoes deformation, fracture, or rust;

    2. Non professionals are strictly prohibited from repairing deformed Intralasik Flap Spatula.


    [Instructions for Use]

    1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;

    2. After use, Intralasik Flap Spatula should be cleaned promptly.


    [Product maintenance and upkeep methods]

    1. After the surgery, any remaining stains on the Intralasik Flap Spatula should be promptly rinsed off and dried for later use.

    2. Intralasik Flap Spatula should be stored in a box with soft material padding to prevent collisions between Intralasik Flap Spatula and damage to the eyelash hook head.


    [Storage]

    Intralasik Flap Spatula should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years



    • User name Member Level Quantity Specification Purchase Date
    • Satisfaction :
    No evaluation information