Your Location:
Product parameters
    Description

    Specifications: 

    SS5014G 65x17 adjustable half eyelashes, SS5014T 65x17 adjustable half eyelashes, SS5015G 65x17 adjustable half eyelashes, SS5015T 65x17 adjustable half eyelashes, SS5017G 82x14 adjustable peripheral opening, SS5017T 82x14 adjustable fixed opening, SS5010G 65x13 adjustable sealing, SS5011G 65x13 adjustable opening, SS5011T 65x13 adjustable opening, SS5012G 65x13 adjustable opening, SS5012T 65x13 adjustable opening, SS5012T 65x13 adjustable opening, SS5009G 52x14 demagnetized eyelash type, SS5009T 52x14 demagnetized eyelash type



    [Product Name]:

     Eyelid Opener


    [Model/Specification]:

     Fixed sealing type, fixed eyelash cover type, infant and toddler type, translational eyelash cover type, steel wire open type, steel wire eyelash cover type.


    [Name of Filing Person/Production Enterprise]

    Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise]

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address]: No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [After sales Service Unit] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Production Filing Certificate No.] Susu Food and Drug Supervision Instrument Production Preparation No. 20194005


    [Medical Device Filing Certificate Number]


    [Product Technical Requirements Number]

    The performance, structural composition, and scope of application of the product are composed of a head and a handle, with a round and blunt head end. There are plate type, steel wire type, translational type, fixed type, and rotary rod type. Made of 06Cr19Ni10 material specified in GB/T 1220-2007, TC4 material specified in GB/T 3621-2007, and titanium wire material specified in GB/T 3623-2007. Non sterile provision. The product has good corrosion resistance, a smooth surface, and is sterilized by the user according to the instructions before use. Used to expand and support eye tissue.


    [Contraindications] None


    [Precautions ]

    During high-pressure steam sterilization, it must not be closed or collide with other objects, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the connection to break. Used by professional medical personnel.


    [Warning]

    1. It is strictly prohibited to use the eyelid opener when it deforms, breaks, or rusts;

    2. Non professionals are strictly prohibited from repairing deformed eyelid openers.


    [Instructions for Use]

    1. High temperature and high pressure sterilization is required before use of the product;

    2. After use, the eyelid opener should be cleaned promptly.


    [Product maintenance and upkeep methods]

    1. After the surgery, the remaining stains on the eyelid opener should be washed clean and dried for later use.

    2. The eyelid opener should be stored in a box with soft materials as padding to prevent collision between the eyelids and damage to the head of the opener.


    [Storage]

    The eyelid opener should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years