Specifications:
SS4001G 120 angle T-head, SS4001T 120 angle T-head, SS4002G 120 angle round head, SS4002T 120 angle round head,
SS4003G120 angle spherical head, SS4003T 120 angle spherical head, SS4005G 120 angle Y-head, SS4005T 120 angle Y-head,
SS4006G 120 straight Y-shaped head, SS4006T 120 straight Y-shaped head, SS4007G 120 angle K-shaped head, SS4007T 120 angle K-shaped head,
SS4008G 120 angle water droplet head, SS4008T 120 angle water droplet head
[Product Name]
Crystal Positioning Hook
[ Model/Specification ]
Angular T-shaped head, angular spherical head, angular Y-shaped head, angular droplet shaped head, and angular K-shaped head.
[Name of Filing Person/Production Enterprise]
Suqian Shengshi Medical Equipment Co., Ltd
[Name and Address of Filing Person/Production Enterprise]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[Production Address]
No. 36 Shuanggou West Road, Sihong County Economic Development Zone
[After sales Service Unit]
Suqian Shengshi Medical Equipment Co., Ltd
[Production Filing Certificate No.]
Susu Food and Drug Supervision Instrument Production Preparation No. 20194005
[Medical Device Filing Certificate Number]
[Product Technical Requirements Number]
The product's performance, structural composition, and scope of application are composed of a head and a rod, with a hook head on the head. Made of 06Cr19Ni10 material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, smooth surface, and good traction function. Before use, the user organization sterilizes it according to the instructions. Used for hooking and pulling eye tissue.
[Contraindications] None
[ Precautions ] During high-pressure steam sterilization, it is absolutely not allowed to collide with other objects, otherwise it will affect the use function. In addition, during high-pressure steam sterilization, thermal expansion can also cause head breakage. Operated by professional medical personnel.
[Warning]
1. It is strictly prohibited to use the crystal positioning hook when it deforms, fractures, or rusts;
2. Non professionals are strictly prohibited from repairing deformed crystal positioning hooks.
[Instructions for Use]
1. The product should be kept at 120 ℃ and sterilized for 25 minutes before use;
2. After use, the crystal positioning hook should be cleaned in a timely manner.
[Product maintenance and upkeep methods]
1. After the surgery, any remaining stains on the lens alignment hook should be washed clean and dried for later use.
2. The crystal positioning hook should be stored in a box with soft materials as padding to prevent collision between the crystal positioning hooks and damage to the head of the crystal positioning hook.
[Storage]
The crystal positioning hook should be stored indoors with a relative humidity of no more than 80%, no corrosive gas, and good ventilation.
[Production Date]
Please refer to the label for details
[Service life]
8 years