  • Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps
    ❤ Add to collection
  • Roller forceps, trachoma forceps, massage forceps, eyelid flap forceps

    Specifications: SS1416G 105xd3mm,SS1416T105xd3mm

    • ¥0.00
      ¥0.00
      ¥0.00
      ¥0.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.00KG
    • Quantity:
    • (Inventory: 199998)
Product parameters
    Description

    Specifications: SS1416G 105xd3mm,SS1416T105xd3mm


    Specification Product Name: Trachoma Forceps


    [Model/Specification] 

    SS1416G 105xd3mm, SS1416T105xd3mm


    [Name of Filing Person/Production Enterprise] 

    Suqian Shengshi Medical Equipment Co., Ltd


    [Name and Address of Filing Person/Production Enterprise] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Address] 

    No. 36 Shuanggou West Road, Sihong County Economic Development Zone


    [Production Filing Certificate No.] 

    Susu Food and Drug Supervision Instrument Production Preparation No. 20194005

    The product's performance, structural composition, and scope of application are composed of a pair of tail stacked blades. Made of 05Cr17Ni4Cu4Nb material specified in GB/T 1220-2007 or TC4 material specified in GB/T 3621-2007. Non sterile provision. The product has good corrosion resistance, a smooth surface, and is sterilized by the user according to the instructions before use. Used for gripping eye tissue and intraocular foreign bodies.


    [Contraindications] None


    [ Precautions ] 

    During high-pressure steam sterilization, the roller tweezers must not be closed, otherwise it will affect the sterilization effect. In addition, during high-pressure steam sterilization, thermal expansion can also cause the tail rivet to break. Used by professional medical personnel.


    [Warning] 

    1. It is strictly prohibited to use roller tweezers when they deform, break, or rust;

    2. Non professionals are strictly prohibited from repairing deformed roller tweezers.


    [Instructions for Use]

    1. High temperature and high pressure sterilization is required before use of the product;

    2. After use, the roller tweezers should be cleaned promptly.


    [Product maintenance and upkeep methods]

    1. After the surgery, the remaining stains on the roller forceps should be washed clean and dried for later use;

    2. The roller tweezers should be stored in a box with soft materials as padding to prevent collision between the rollers and damage to the inner surface of the roller tweezers head.


    [Storage]

    Roller tweezers should be stored indoors with a relative humidity of no more than 80%, no corrosive gases, and good ventilation.


    [Production Date] 

    Please refer to the label for details


    [Service life]

    8 years